TM 5-3895-373-20
B.
INSTALL Continued.
2.
CONNECT DCA HARNESS.
a.
Install ground wires (26 and 27) and secure
wires and equipment panel (31) with machine
screws (25).
b.
Install code resistor (24) and sensor circuit
resistors (23) on terminal board (29).
c.
Refer to wiring diagram and install DCA harness
wires (17 through 22) on terminal board (29).
Secure wires and resistors (23 and 24) with
terminal screws (16).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
d.
Apply even coating of electrical insulating
varnish to terminals of installed harness wires
(17 through 22), resistors (23 and 24), and
ground wires (26 and 27).
GO TO NEXT PAGE
7-127