TM 5-3895-373-20B.INSTALL Continued.2.CONNECT DCA HARNESS.a.Install ground wires (26 and 27) and securewires and equipment panel (31) with machinescrews (25).b.Install code resistor (24) and sensor circuitresistors (23) on terminal board (29).c.Refer to wiring diagram and install DCA harnesswires (17 through 22) on terminal board (29).Secure wires and resistors (23 and 24) withterminal screws (16).Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.d.Apply even coating of electrical insulatingvarnish to terminals of installed harness wires(17 through 22), resistors (23 and 24), andground wires (26 and 27).GO TO NEXT PAGE7-127