TM 5-3895-373-207.17.REPLACE DCA AND PRESSURE TRANSMITTERS Continued.B.INSTALL Continued.7.INSTALL TACHOMETER SIGNALGENERATOR AND ENGINE COOLANTTEMPERATURE TRANSDUCER.a.Install tachometer signal generator (55) inmating drive angle. Make sure signal generatorcable lines up and seats in cable port of driveangle. Tighten tachometer signal generatorswivel nut with crowfoot wrench.b.Apply electrical insulating compound toconnector plug of tachometer signal generator(55).c.Plug connector plug of tachometer signalgenerator (55) into mating DCA harnessconnector.d.Remove pipe plug from pipe bushing (57).Install and tighten engine coolant temperaturetransducer (56) into pipe bushing. Use backupwrench, if necessary.e.Apply electrical insulating compound toconnector plug of engine coolant temperaturetransducer (56).f.Plug connector plug of engine coolanttemperature transducer (56) into mating DCAharness connector.GO TO NEXT PAGE7-132