TM 5-3895-373-207.17.REPLACE DCA AND PRESSURE TRANSMITTERS - Continued.B.INSTALL.1.INSTALL BRACKET, DCA HOUSING,AND TERMINAL BOARD.Thread locking compound solventcan cause eye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If solvent contactseyes, flush eyes with water and getimmediate medical attention.a.Clean bolts (32) with thread lockingcompound solvent. Wipe bolts dry withcleaning cloth.b.Position bracket (35) against enginecowling and secure in place with lockscrews (37) and self-locking nuts (36).c.Position DCA housing (34) on bracket(35), in line with mounting holes.d.Install flat washers (33) on bolts (32).Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.e.Coat threads of bolts (32) with threadlocking compound.f.Install bolts (32). Tighten to 11 lb-ft (15N•m).g.Install machine screws (28) and terminalboard (29).h.Place equipment panel (31) inside of DCAhousing (34). Install and tighten twomachine screws (30) in opposite cornersof housing.GO TO NEXT PAGE7-126