TM 5-3895-373-20A.REMOVE - Continued.8.REMOVE INSTRUMENT SHUNT.Disconnect batteries prior toperforming maintenance inimmediate battery or starter area.Failure to disconnect batteries maylead to electrical shock or shortcircuit and result in severe personnelinjury or damage to equipment.a.Unbuckle battery box holddown straps(58) and remove battery box covers (59)from both batteries.When disconnecting batteries,disconnect negative battery cablebefore disconnecting positive batterycable. Failure to disconnect batteriesin the proper sequence may lead toelectrical shock or short circuit andresult in severe personnel injury.b.Remove battery terminal caps (60) andbattery nuts (61). Disconnect negativebattery cable (62) and positive batterycable (63) from batteries.c.Remove hex head cap screws (64),lockwashers (65), negative terminal lead(66), and ground cable (67).d.Remove machine screws (68),lockwashers (69), and flat washers (70).Discard lockwashers.e.Tag and remove shunt leads 338 (71) and337 (72).f.Remove self-locking screws (73) andinstrument shunt (74). Discard self-locking screws.GO TO NEXT PAGE7-125