TM 5-3895-373-20
7.17.
REPLACE DCA AND PRESSURE TRANSMITTERS Continued.
B.
INSTALL Continued.
3.
INSTALL DCA HOUSING COVER.
NOTE
Toggle switch "ON" markings should
face toward front of housing cover
(2).
a.
Install engine crank toggle switch (10) and zero
offset toggle switch (13) into housing cover (2).
b.
Install lockwashers (15) and hex nuts (14) onto
engine crank toggle switch (10) and zero offset
toggle switch (13).
c.
Connect wires 314 (11) and 315 (12) to zero
offset toggle switch (13). Refer to wiring
diagram below.
d.
Connect wires 151 (8) and 322 (9) to engine
crank toggle switch (10).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
e.
Apply even coating of electrical insulating
varnish to terminals of toggle switches (10 and
13).
f.
Install DCA harness connector (7) and electrical
component cover (4) with machine screws (3),
flat washers (5), and hex nuts (6).
g.
Using flat head bit from screwdriver bit set,
install housing cover (2) and screws (1).
GO TO NEXT PAGE