TM 5-3895-373-204.11. REPLACE INDUCTION HEATER RELAY - Continued.B. INSTALL Continued.3. INSTALL BATTERY CABLES.When connecting batteries, connectpositive battery cable beforeconnecting negative battery cable.Failure to connect batteries in theproper sequence may lead toelectrical shock or short circuit andresult in severe personnel injury.a.Reconnect positive battery cable (6) and batterynut (4) to positive terminal of inboard battery.b.Reconnect negative battery cable (5) and batterynut (4) to negative terminal of outboard battery.Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.c.Apply electrical insulating varnish to terminals onbattery.d.Install rubber battery terminal caps (3) ontobattery terminals.e.Install battery box covers (2) on both batteriesand buckle battery box holddown straps (1).NOTEFOLLOW-ON-TASKS: Close rear top left access door per TM 5-3895-373-10.Install left access cover per TM 5-3895-373-10.END OF TASK4-68
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business