TM 5-3895-373-20
4.11.
REPLACE INDUCTION HEATER RELAY - Continued.
B. INSTALL Continued.
3. INSTALL BATTERY CABLES.
When connecting batteries, connect
positive
battery
cable
before
connecting negative battery cable.
Failure to connect batteries in the
proper
sequence
may
lead
to
electrical shock or short circuit and
result in severe personnel injury.
a.
Reconnect positive battery cable (6) and battery
nut (4) to positive terminal of inboard battery.
b.
Reconnect negative battery cable (5) and battery
nut (4) to negative terminal of outboard battery.
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
c.
Apply electrical insulating varnish to terminals on
battery.
d.
Install rubber battery terminal caps (3) onto
battery terminals.
e.
Install battery box covers (2) on both batteries
and buckle battery box holddown straps (1).
NOTE
FOLLOW-ON-TASKS: Close rear top left access door per TM 5-3895-373-10.
Install left access cover per TM 5-3895-373-10.
END OF TASK
4-68