TM 5-3895-373-20
B. INSTALL Continued.
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact
with
eyes.
If
compound
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Apply thread locking compound to threads of hex
head cap screws (16).
d.
Install relay (18) and ground wire G201 (15) with
flat washers (17) and hex head cap screws (16).
Tighten cap screws to 9 lb-ft (12 Nm).
2.
CONNECT RELAY WIRES TO RELAY.
a. Install ground wire G201 (15) and wire 164 (14)
to relay coil terminals.
b. Install flat washers (13) and hex nuts (12) onto
both relay coil terminals. Tighten hex nuts to 18
lb-in (0,9 Nm).
c. Install wire 165 (11), wire 103 (10), and wire 166
(9) to relay switch terminals.
d. Install flat washers (8) and hex nuts (7) onto both
relay switch terminals, Tighten hex nuts to 65 lb-
in (7,3 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
e. Apply electrical insulating varnish to relay
terminals.
GO TO NEXT PAGE
4-67