TM 5-3895-373-20
4.10.
REPLACE COLD START INDUCTION HEATER - Continued.
B.
INSTALL.
1.
INSTALL INDUCTION HEATER.
Anti-seize compound can cause eye
damage. Wear safety goggles/glasses
when using. Avoid contact with eyes.
If compound contacts eyes, flush
eyes with water and get immediate
medical attention.
a.
Coat threads and mating surface of new
induction heater (5) with anti-seize compound.
b.
Install induction heater (5) and tighten to 10 lb-ft
(14 Nm) using crowfoot socket wrench.
c.
Apply electrical insulating compound to induction
heater terminal.
d.
Connect lead wire electrical contact (9) to
induction heater terminal.
2.
CONNECT INDUCTION HEATER FUEL PIPE.
a.
Install compression sleeves (7 and 8) on fuel
pipe (4).
b.
Slide fuel pipe through clamp and into fuel filter
multiple connector (6) and induction heater (5).
Do not overtighten tube coupling
nuts. Overtightening may damage
compression
sleeve
and
cause
leakage.
c.
Tighten tube coupling nuts (I and 3). Do not
overtighten tube coupling nuts.
NOTE
FOLLOW-ON-TASKS: Close front top left access door per TM 5-3895-373-10.
Close front top right access door per TM 5-3895-373-10.
Install engine access cover per paragraph 2.22.
END OF TASK
4-64