TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
AUGER ASSEMBLY FAILS TO RAISE
INITIAL SETUP:
Test Equipment
References -- Continued
Hydraulic test kit (WP 0440, Vol 3, Item 59)
Personnel Required
91L
WP 0289, Vol 2
Assistant
WP 0291, Vol 2
References
WP 0297, Vol 2
WP 0312, Vol 2
WP 0408, Vol 2
WP 0441, Vol 3
WP 0442, Vol 3
WP 0449, Vol 3
Equipment Conditions
Engine off (TM 5-3895-385-10)
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Augers Fail to Raise Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start Bituminous Material Paving
screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to raise augers using
keypad (TM 5-3895-385-10).
3. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
2. If no fault is found, proceed to
next test.
4. Check fault screen for AUGER
1. If fault is found, proceed to WP
UP fault.