Table 1. Augers Fail to Lower Troubleshooting Procedures -- Continued
Table 1. Augers Fail to Raise Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  414    415    416    417    418  419  420    421    422    423    424  
img
. . . . . . . . . . . . . .
TM 5-3895-385-23-1
0092
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
AUGER ASSEMBLY FAILS TO RAISE
INITIAL SETUP:
Test Equipment
References -- Continued
Hydraulic test kit (WP 0440, Vol 3, Item 59)
WP 0190
Personnel Required
WP 0191
91L
WP 0289, Vol 2
Assistant
WP 0291, Vol 2
References
WP 0297, Vol 2
WP 0095
WP 0312, Vol 2
WP 0106
WP 0408, Vol 2
WP 0181
WP 0441, Vol 3
WP 0184
WP 0442, Vol 3
WP 0185
WP 0449, Vol 3
WP 0186
Equipment Conditions
Engine off (TM 5-3895-385-10)
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Augers Fail to Raise Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start Bituminous Material Paving
screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to raise augers using
keypad (TM 5-3895-385-10).
3. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0181.
2. If no fault is found, proceed to
next test.
4. Check fault screen for AUGER
1. If fault is found, proceed to WP
UP fault.
0095.
0092-1