TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
AUGER UP FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
WP 0376, Vol 2
Personnel Required
WP 0399, Vol 3
91L
WP 0443, Vol 3
Assistant
WP 0451, Vol 3
References
Equipment Conditions
Engine off (TM 5-3895-385-10)
WP 0312, Vol 2
Hydraulic oil cool (TM 5-3895-385-10)
WP 0373, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Auger Up Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start Bituminous Material Paving
screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to raise auger using
keypad (TM 5-3895-385-10).
3. Check fault screen for SCREED
1. If fault is found, proceed to (WP
CONTROLLER OFFLINE fault.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next
malfunction.
1. Disconnect main manifold wiring
harness W10 J3 from auger up
Figure 28).