TM 5-3895-385-23-1
0091
Table 1. Augers Fail to Lower Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE HORN KEYPAD
fault.
2. If no fault is found, proceed to
next test.
6. Check fault screen for RIGHT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
fault.
2. If no fault is found, proceed to
next test.
7. Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
fault.
2. If no fault is found, proceed to
next test.
8. Check fault screen for RIGHT
1. If fault is found, proceed to WP
SCREED AUG/CONV KEYPAD
fault.
2. If no fault is found, proceed to
next test.
9. Check fault screen for LEFT
1. If fault is found, proceed to WP
SCREED AUG/CONV KEYPAD
fault.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next malfunction.
2. Auger lift hydraulic cylinder leak.
1. Check for auger lift hydraulic
1. If leaks are found, replace auger
cylinder leaks (WP 0408, Vol 2).
lift hydraulic cylinder seals (WP
0408, Vol 2).
2. If no leak or damage is found,
proceed to next malfunction.
3. Auger lift hydraulic hose leak.
Check all hydraulic hoses from main
1. If leaks or damage is found,
hydraulic manifold to auger lift
replace damaged hydraulic
hydraulic cylinder for leaks or
hose (WP 0289, Vol 2) and (WP
pinches (WP 0289, Vol 2) and (WP
0297, Vol 2).
0297, Vol 2).
0091-2