Table 1. Augers Fail to Lower Troubleshooting Procedures -- Continued
AUGER ASSEMBLY FAILS TO RAISE

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  413    414    415    416    417  418  419    420    421    422    423  
img
TM 5-3895-385-23-1
0091
Table 1. Augers Fail to Lower Troubleshooting Procedures -- Continued.
MALFUNCTION
MALFUNCTION
MALFUNCTION
7. Loss of hydraulic pressure at
1. Attach hydraulic pressure tester
right side auger lift hydraulic
(WP 0442, Vol 3) to hydraulic
cylinder.
hose 76 at right side auger lift
hydraulic cylinder (WP 0297, Vol
2).
2. Start BMPM engine (TM 5-3895-
385-10).
3. Press auger lower key on
pedestal top (TM 5-3895-385-
10).
4. Check hydraulic pressure (WP
1. If hydraulic pressure reads a
0442, Vol 3) at hydraulic hose 76
minimum of 1800 psi (12,410
at right side auger lift hydraulic
kPa), replace the right side
cylinder (WP 0297, Vol 2) while
auger lift hydraulic cylinder (WP
pressing auger lower key on
0408, Vol 2).
pedestal top (TM 5-3895-385-
10).
2. If pressure reads below 1800 psi
(12,410 kPa), replace hydraulic
hose 76 (WP 0297, Vol 2).
END OF WORK PACKAGE