TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
33. Left Console Left Joy Cal fault
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
indicated on fault screen (WP
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
34. Left Console Right Joy Cal fault
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
indicated on fault screen (WP
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
35. High hydraulic oil temperature
Check hydraulic oil temperature.
indicator lit.
2. Check hydraulic oil temperature
3. Notify field maintenance.
36. HYD Temp Sensor fault
Note fault indicated.
Notify field maintenance.
indicated on fault screen (WP
37. Engine fails to crank or cranks
1. Check that BATTERY
1. Set BATTERY DISCONNECT
slowly.
DISCONNECT switch is set to
switch to ON position.
2. If conditions are met, proceed
to next test.
2. Check for proper BMPM setup
1. Ensure BATTERY
DISCONNECT switch is set to
2. Ensure desired (left or right)
control pedestal is set to RUN
position and the other control
pedestal is set to STOP position
3. Ensure all joysticks are in the
4. If conditions are met, proceed
to next test.