Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.
13. Reverse Alarm fault indicated
Note fault indicated.
Notify field maintenance.
14. Horn fails to sound.
1. Check for Horn Relay fault
1. If no fault is found, proceed to
indicated on fault screen (WP
next test.
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
1. Ensure BATTERY
DISCONNECT switch is set to
2. Ensure BMPM keyless engine
switch is set to AUX position
3. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.
4. Attempt operation with opposite
1. If opposite horn keypad
(left or right) horn keypad (WP
accomplishes operation, notify
field maintenance.
WARNING
Do not operate BMPM if EMERGENCY STOP switch fails to shut down BMPM. Failure to comply
may cause injury or death to personnel or damage to equipment.
15. EMERGENCY STOP switch
Note malfunctioning EMERGENCY
1. Turn keyless engine switch to
fails to shut down BMPM.
STOP switch.
2. Notify field maintenance.