TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
44. Engine Enable Relay fault
Note fault indicated.
Notify field maintenance.
indicated on fault screen (WP
45. Engine J1939 Offline fault
Note fault indicated.
Notify field maintenance.
indicated on fault screen (WP
46. Any fault indicated on engine
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault screen.
2. If blown fuse is not found,
proceed to next test.
2. Note fault code on display
Notify field maintenance.
screen.
47. Low battery indicator lit.
Inspect battery connectors and
Notify field maintenance if problem
cables for damage or corrosion (WP
persists.
48. Propel Controller Offline fault
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
indicated on fault screen (WP
2. If blown fuse is not found,
proceed to next test.
2. Note fault code on display
Notify field maintenance.
screen.
49. Screed Controller Offline fault
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
indicated on fault screen (WP
2. If blown fuse is not found,
proceed to next test.
2. Note fault code on display
Notify field maintenance.
screen.
50. Output Module Offline fault
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
indicated on fault screen (WP
2. If blown fuse is not found,
proceed to next test.
2. Note fault code on display
Notify field maintenance.
screen.
51. Right Sonic Sensor fault
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
indicated on fault screen (WP
2. If blown fuse is not found,
proceed to next test.