TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
18. Spraydown fails to operate.
1. Check for Spray Pump fault
1. If no fault is found, proceed to
indicated on fault screen (WP
next test.
2. If fault is found, notify field
maintenance.
WARNING
Cleaning solvent is combustible and toxic to eyes, skin, and respiratory tract. Skin and eye
protection is required. Avoid repeated or prolonged contact. Work in ventilated area only. Failure
to comply may cause injury or death to personnel.
2. Check for proper BMPM setup
1. Ensure cleaner solution tank is
2. Ensure BATTERY
DISCONNECT switch is set to
3. Ensure BMPM keyless engine
switch is set to AUX position
4. Ensure spraydown pump
shutoff valve is in the open
5. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.
4. Attempt operation with opposite
If opposite beacon keypad
(left or right) beacon keypad
accomplishes operation, notify field
maintenance.
19. Left Console Beacon Key Pad
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault indicated on fault screen
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.