• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.

Technical Manual For Bituminous Material Paving Machine (Bmpm) Page Navigation
  169    170    171    172    173  174  175    176    177    178    179  
img
. . . . . . . . . .
TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
There are m any points o n the BMPM where perso nnel could be injured by moving part s. Turn
BMPM off before performing maintenance. Care should be taken to avoid any pinch points when
performing maintenance. Failure to comply may cause injury or death to personnel.
4. Check for obstructed movement.
1. Remove any obstructions
around auger.
2. If no obstructions are found,
proceed to next test.
5. Ensure sonic auger sensors are
1. Ensure sonic auger sensors are
connected properly.
installed properly (WP 0006).
2. Ensure pile height setting is
properly adjusted (WP 0006).
6. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
as necessary (WP 0019).
2. Notify field maintenance if
problem persists.
56. Right auger fails to turn.
1. Check for Right Auger Reverse
1. If no fault is found, proceed to
EDC fault or Right Auger
next test.
Forward EDC fault indicated on
2. If fault is found, notify field
fault screen (WP 0004).
maintenance.
2. Check for proper BMPM setup
1. Ensure engine is on (WP 0006).
(WP 0006).
2. Ensure auger/conveyor bypass
is off (WP 0004).
3. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
(WP 0008).
fuse (WP 0008).
2. If blown fuse is not found,
proceed to next test.
0011-22