TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
There are m any points o n the BMPM where perso nnel could be injured by moving part s. Turn
BMPM off before performing maintenance. Care should be taken to avoid any pinch points when
performing maintenance. Failure to comply may cause injury or death to personnel.
4. Check for obstructed movement.
1. Remove any obstructions
around auger.
2. If no obstructions are found,
proceed to next test.
5. Ensure sonic auger sensors are
1. Ensure sonic auger sensors are
connected properly.
2. Ensure pile height setting is
6. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
2. Notify field maintenance if
problem persists.
56. Right auger fails to turn.
1. Check for Right Auger Reverse
1. If no fault is found, proceed to
EDC fault or Right Auger
next test.
Forward EDC fault indicated on
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
2. Ensure auger/conveyor bypass
3. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.