TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Ensure sonic auger sensor is
Notify field maintenance if problem
persists.
52. Left Sonic Sensor fault
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
indicated on fault screen (WP
2. If blown fuse is not found,
proceed to next test.
2. Ensure sonic auger sensor is
Notify field maintenance if problem
persists.
53. Left Auger Reverse EDC fault
Note fault indicated.
Notify field maintenance.
indicated on fault screen (WP
54. Left Auger Forward EDC fault
Note fault indicated.
Notify field maintenance.
indicated on fault screen (WP
55. Left auger fails to turn.
1. Check for Left Auger Reverse
1. If no fault is found, proceed to
EDC fault or Left Auger Forward
next test.
EDC fault indicated on fault
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
2. Ensure auger/conveyor bypass
3. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.