Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.

Technical Manual For Bituminous Material Paving Machine (Bmpm) Page Navigation
  162    163    164    165    166  167  168    169    170    171    172  
img
. . . . . . . . . . . . . . . . . . . . . .
TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
20. Left Console Horn Key Pad
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault indicated on fault screen
(WP 0008).
fuse (WP 0008).
(WP 0004).
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
21. Left Console Lights Key Pad
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault indicated on fault screen
(WP 0008).
fuse (WP 0008).
(WP 0004).
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
22. Right Console Beacon Key Pad
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault indicated on fault screen
(WP 0008).
fuse (WP 0008).
(WP 0004).
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
23. Right Console Horn Key Pad
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault indicated on fault screen
(WP 0008).
fuse (WP 0008).
(WP 0004).
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
24. Right Console Lights Key Pad
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault indicated on fault screen
(WP 0008).
fuse (WP 0008).
(WP 0004).
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
25. Left Screed Aug/Conv Key Pad
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
fault indicated on fault screen
(WP 0008).
fuse (WP 0008).
(WP 0004).
2. If blown fuse is not found,
proceed to next test.
2. Note fault indicated.
Notify field maintenance.
26. Right Screed Aug/Conv Key
1. Check fuse box for blown fuse
1. If blown fuse is found, replace
Pad fault indicated on fault
(WP 0008).
fuse (WP 0008).
screen (WP 0004).
2. If blown fuse is not found,
proceed to next test.
0011-15