Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
16. Work lights fail to operate.
1. Check for Light Relay fault
1. If no fault is found, proceed to
indicated on fault screen (WP
next test.
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
1. Ensure BATTERY
DISCONNECT switch is set to
2. Ensure BMPM keyless engine
switch is set to AUX position
3. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.
4. Attempt operation with opposite
1. If opposite lights keypad
(left or right) lights keypad (WP
accomplishes operation, notify
field maintenance.
17. Beacon light fails to operate.
1. Check for Beacon Relay fault
1. If no fault is found, proceed to
indicated on fault screen (WP
next test.
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
1. Ensure BATTERY
DISCONNECT switch is set to
2. Ensure BMPM keyless engine
switch is set to AUX position
3. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.
4. Attempt operation with opposite
If opposite beacon keypad
(left or right) beacon keypad
accomplishes operation, notify field
maintenance.