TM 5-3895-373-34
C.
INSTALL - Continued.
6.
INSTALL TOW POINT FLOW DIVIDER.
Pipe sealant can cause eye damage or
skin irritation. Wash after skin contact.
Wear
safety
goggles/glasses
when
using. Avoid contact with eyes or skin.
If sealant contacts eyes, flush eyes with
water
and
get
immediate
medical
attention.
a.
Place tow point flow divider (108) into a bench
vise. Apply pipe sealant to exposed threads of
elbow (110).
b.
Connect pipe coupling (109) on tow point flow
control valve (45) to elbow (110). Tighten
coupling so that flow control valve is positioned
across top of tow point flow divider (108) as
shown in illustration.
c.
Remove tow point flow divider (108) from bench
vise. Place tow point flow divider onto mounting
holes on tow point mount plate while aligning
elbows with hydraulic tubes.
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound contacts
eyes, flush eyes with water and get
immediate medical attention.
d.
Apply thread locking compound to threads of
bolts (107).
e.
Install bolts (107) through bottom of tow point
mount plate. Install flat washers (106) and hex
nuts (105). Tighten hex nuts.
GO TO NEXT PAGE
2-777