TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL Continued.
10.
INSTALL TOW POINT MOUNT PLATE.
a.
Position tow point mount plate (71) onto the
valve panel over mounting holes.
b.
Install flat washers (70) onto bolts (69).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound contacts
eyes, flush eyes with water and get
immediate medical attention.
c.
Apply thread locking compound to threads of
bolts (69).
NOTE
Connect hydraulic tubes loosely prior to
tightening bolts, to ensure alignment of
hydraulic tubes.
d.
Install bolts (69) through tow point mount plate
(71) and into valve panel. Tighten bolts to 37 lb-
ft (50 N.m).
GO TO NEXT PAGE
2-782