TM 5-3895-373-342.55REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.C.INSTALL Continued.10.INSTALL TOW POINT MOUNT PLATE.a.Position tow point mount plate (71) onto thevalve panel over mounting holes.b.Install flat washers (70) onto bolts (69).Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compound contactseyes, flush eyes with water and getimmediate medical attention.c.Apply thread locking compound to threads ofbolts (69).NOTEConnect hydraulic tubes loosely prior totightening bolts, to ensure alignment ofhydraulic tubes.d.Install bolts (69) through tow point mount plate(71) and into valve panel. Tighten bolts to 37 lb-ft (50 N.m).GO TO NEXT PAGE2-782