TM 5-3895-373-34
C.
INSTALL - Continued.
9.
INSTALL TUBES AND HOSES ONTO LEFT
AUGER/CONVEYOR SPEED CONTROL VALVE.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
a.
Apply hydraulic fitting sealant to exposed threads
on tube reducer (93), straight adapters (89 and
85), and elbows (88 and 91).
b.
Connect tube (86) to elbow (88). Tighten tube.
c.
Connect tubes (87 and 84) to straight adapters
(89 and 85). Tighten tubes.
d.
Connect hoses (90 and 92) to elbow (91) and
tube reducer (93). Tighten hoses.
GO TO NEXT PAGE
2-781