TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL - Continued.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
f.
Apply hydraulic fitting sealant to elbows (103 and
104) and straight adapters (51 and 100).
g.
Connect swivel tee (50) to straight adapter (100).
NOTE
It may be necessary to loosen tube
fittings on opposite ends of tubes to
align tubes with mating fittings on tow
point flow divider.
h.
Connect tube (101) to elbow (103). Tighten
tube.
i.
Connect tube (102) to elbow (104). Tighten
tube.
j.
Connect tube (49) to straight adapter (51).
Tighten tube.
GO TO NEXT PAGE
2-778