TM 5-3895-373-34
C.
INSTALL - Continued.
5.
INSTALL TOW POINT CONTROL VALVES.
a.
Place tow point control valve (46 or 47) onto
mounting holes on tow point mount plate.
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound contacts
eyes, flush eyes with water and get
immediate medical attention.
b.
Apply thread locking compound to the threads of
bolts (122).
c.
Install bolts (122), flat washers (121), and hex
nuts (120). Do not tighten hex nuts.
GO TO NEXT PAGE
2-775