TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL Continued.
8.
INSTALL TUBES AND HOSES ONTO RIGHT
AUGER/CONVEYOR SPEED CONTROL VALVE.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
a.
Apply hydraulic fitting sealant to exposed threads
on straight adapter (74), tube reducer (82), and
elbows (77, 78, and 80).
b.
Connect tubes (75 and 76) to elbows (77 and
78). Tighten tubes.
Ensure
tube
(76)
is
tightened at both ends, as it was loosened during
removal.
c.
Connect hose (79) to elbow (80). Tighten hose.
d.
Connect tube (73) to straight adapter (74).
Tighten tube.
e.
Connect hose (81) to tube reducer (82). Tighten
hose.
GO TO NEXT PAGE
2-780