TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL - Continued.
NOTE
Step d is for installing the rear tow point
control valve and step e is for installing
the front tow point control valve.
d.
Connect rear tow point control valve (47) to
hydraulic
fittings.
Perform
the
following
procedures.
Hydraulic fitting sealant can cause eye
damage or skin irritation.
Wash
after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
(1)
Apply hydraulic fitting sealant to exposed
threads of straight adapters (117 and 119)
and elbow (104).
(2)
Connect tube (118) to straight adapter
(119). Do not tighten tube.
(3)
Install tube (116) between straight adapter
(117) and elbow (104). Do not tighten
tube.
e.
Connect front tow point control valve (46) to
hydraulic
fittings.
Perform
the
following
procedures.
(1)
Apply hydraulic fitting sealant to threads of
swivel tee (50), elbow (103), tee (112),
and elbow (114).
(2)
Install tube (111) between swivel tee (50)
and tee (112). Do not tighten tube.
(3)
Connect tube (115) to tee (112). Do not
tighten tube.
(4)
Install tube (113) between elbow (103) and
elbow (114). Do not tighten tube.
f.
Tighten hex nuts (120) to 19 lb-ft (26 Nm) and
tighten all tubes in steps d and e.
GO TO NEXT PAGE
2-776