TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL - Continued.
NOTE
It may be necessary to connect hydraulic
tubes to auger/conveyor control valve
ports before bolts are tightened per step
d.
b.
Install lockwashers (136) onto bolts (135).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound contacts
eyes, flush eyes with water and get
immediate medical attention.
c.
Apply thread locking compound to the threads of
bolts (135).
d.
Install lockwashers (136) and bolts (135).
Tighten bolts to 19 lb-ft (26 Nm).
GO TO NEXT PAGE
2-772