TM 5-3895-373-20
15.18. REPAIR TWO FOOT AUGER AND FENDER EXTENSION - Continued.
D.
ASSEMBLE - Continued.
2.
ASSEMBLE BEARING MOUNT.
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact. Wear safety goggles/glasses
when using. Avoid contact with eyes
or skin. If sealant contacts eyes,
flush eyes with water and get
immediate medical attention.
a.
Apply pipe sealant to threads on lubrication pipe
(21).
b.
Install and tighten lubrication fitting (20) and
elbow (22) onto lubrication pipe (21).
c.
Apply pipe sealant to threads of elbow (22).
Install and tighten elbow into bearing unit (15).
d.
Position bearing unit (15) on bearing mount
(12). Install hex head cap screws (19) and
lockwashers (18).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
e.
Apply thread locking compound (Item 12,
Appendix C) to threads of hex head cap screws
(19).
f.
Install hex nuts (17) and tighten to 180 Ib-ft (244
Nm) using 1/2 to 3/4 in. socket wrench adapter.
GO TO NEXT PAGE
15-130