TM 5-3895-373-20
A.
DISASSEMBLE Continued.
3.
DISASSEMBLE AUGER FLIGHTS.
a.
Remove hex nuts (23) and lockwashers (24).
Discard lockwashers.
b.
Remove quarter auger flights (25), shaft covers
(26), and teflon flat washers (27). Discard teflon
flat washers.
c.
Remove hex head cap screws (28), hemi auger
flights (29), and teflon flat washers (30). Discard
teflon flat washers.
d.
Separate 1 ft extension shaft (31) from 2 ft
extension shaft (16).
B.
CLEAN.
1.
CLEAN ALL METAL PARTS.
Cleaning solvent, P-D-680, is TOXIC
and
flammable.
Wear
protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for
Type m cleaning solvent is 200°F
(93,30C). Failure to do so may result
in injury or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Clean all metal parts with cleaning solvent.
Scrub off hard deposits with wire scratch brush.
Wipe dry with cleaning cloth.
b.
Clean lubrication components with cleaning
cloth and cleaning solvent. Ensure pipe sealant
is removed from threads of lubrication fitting,
lubrication pipe, and elbow.
GO TO NEXT PAGE
15-127