TM 5-3895-385-23-2
0401
DT STYLE CONNECTOR RECEPTACLE REPAIR
Figure 3. DT Style Connector Receptacle.
1. Remove wedge lock (Figure 3, Item 2) from connector (Figure 3, Item 1).
2. Remove terminal (Figure 3, Item 3) and wire (Figure 3, Item 5) from connector (Figure 3, Item 1).
3. Cut and remove terminal (Figure 3, Item 3) from wire (Figure 3, Item 5).
4. Remove one-quarter of an inch (6 mm) of insulation (Figure 3, Item 4) from end of wire (Figure 3, Item 5).
NOTE
Ensure all strands of wire are inside terminal when installing.
5. Install terminal (Figure 3, Item 3) to wire (Figure 3, Item 5), and crimp terminal.
6. Insert terminal (Figure 3, Item 3) and wire (Figure 3, Item 5) into connector (Figure 3, Item 1) until a click is
felt.
7. Install wedge lock (Figure 3, Item 2) into connector (Figure 3, Item 1).
END OF TASK