• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Left Track Forward EDC Fault Troubleshooting Procedures -- Continued
Table 1. Right Track Reverse EDC Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  618    619    620    621    622  623  624    625    626    627    628  
img
. . . .
TM 5-3895-385-23-1
0151
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
RIGHT TRACK REVERSE EDC FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0373, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0451, Vol 3
References
Equipment Conditions
WP 0180
Engine off (TM 5-3895-385-10)
WP 0320, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Right Track Reverse EDC Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Propel Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for PROPEL
1. If fault is found, turn keyless
CONTROLLER OFFLINE fault.
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to WP 0180.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next test.
2. Propulsion pump malfunction.
1. Locate W1 J18 at propulsion
pump right connector (WP 0451,
Vol 3, Figure 10).
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
0151-1