Table 1. Left Auger Reverse EDC Fault Troubleshooting Procedures -- Continued
LEFT TRACK FORWARD EDC FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  614    615    616    617    618  619  620    621    622    623    624  
img
TM 5-3895-385-23-1
0149
Table 1. Left Auger Reverse EDC Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between known
to next malfunction.
good ground and main wiring
harness W1 J27 Pin C (WP
0451, Vol 3, Figure 10).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
3. Main wiring harness has a short
Measure for continuity (WP 0443,
1. If continuity is present, replace
circuit.
Vol 3) between main wiring harness
main wiring harness (WP 0373,
W1 J2 Pin 44 and all other pins on
Vol 2).
the main wiring harness W1 J2 (WP
0451, Vol 3, Figure 2).
2. If no continuity is present,
replace propel controller module
ECM (WP 0399, Vol 2).
END OF WORK PACKAGE