Table 1. Reverse Alarm Fault Troubleshooting Procedures -- Continued
Table 1. Propel Controller Offline Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  708    709    710    711    712  713  714    715    716    717    718  
img
. . .
TM 5-3895-385-23-1
0180
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
PROPEL CONTROLLER OFFLINE FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0386, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0447, Vol 3
References
WP 0451, Vol 3
WP 0213
Equipment Conditions
WP 0277, Vol 2
Engine off (TM 5-3895-385-10)
WP 0373, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Propel Controller Offline Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Propel controller (Electronic
1. Disconnect main wiring harness
Control Module (ECM)) has
W1 J2 from propel controller
damage or loose pin.
module ECM (WP 0451, Vol 3,
Figures 2).
2. Check propel controller module
1. If propel controller module ECM
ECM for damage or loose pin.
has damage or loose pin,
replace propel controller module
ECM (WP 0399, Vol 2).
2. If no damage is found, proceed
to next test.
3. Check main wiring harness W1
1. If main wiring harness W1 J2
J2 for damage or loose pin.
has damage or loose pin, repair
or replace main wiring harness
(WP 0373, Vol 2).
2. If no damage is found, proceed
to next malfunction.
0180-1