Table 1. Right Track Reverse EDC Fault Troubleshooting Procedures -- Continued
LEFT TRACK REVERSE EDC FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  620    621    622    623    624  625  626    627    628    629    630  
img
TM 5-3895-385-23-1
0151
Table 1. Right Track Reverse EDC Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between known
to next malfunction.
good ground and main wiring
harness W1 J18 Pin C (WP
0451, Vol 3, Figure 10).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Main wiring harness has a short
Measure for continuity (WP 0443,
If continuity is present, replace main
circuit.
Vol 3) between main wiring harness
wiring harness (WP 0373, Vol 2).
W1 J2 Pin 37 and all other pins on
the main wiring harness W1 J2 (WP
0451, Vol 3, Figure 2).
END OF WORK PACKAGE