Table 1. Right Track Reverse EDC Fault Troubleshooting Procedures -- Continued
Table 1. Left Track Reverse EDC Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  621    622    623    624    625  626  627    628    629    630    631  
img
. . . .
TM 5-3895-385-23-1
0152
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
LEFT TRACK REVERSE EDC FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0373, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0451, Vol 3
References
Equipment Conditions
WP 0180
Engine off (TM 5-3895-385-10)
WP 0320, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Left Track Reverse EDC Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Propel Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for PROPEL
1. If fault is found, turn keyless
CONTROLLER OFFLINE fault.
engine switch to the OFF
position (TM 5-3895-385-10) and
proceed to WP 0180.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next test.
2. Propulsion pump malfunction.
1. Locate W1 J25 at propulsion
pump left connector (WP 0451,
Vol 3, Figure 10).
.
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
0152-1