LEFT AUGER REVERSE EDC FAULT
Table 1. Left Auger Reverse EDC Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  613    614    615    616    617  618  619    620    621    622    623  
img
.
TM 5-3895-385-23-1
0149
Table 1. Left Auger Reverse EDC Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Attempt to turn left auger on at
maximum speed in the reverse
direction in manual mode using
keypad (TM 5-3895-385-10).
4. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of
3) between main wiring harness
0.4 Volts Direct Current (VDC),
W1 J27 Pin D and main wiring
replace the variable auger pump
harness W1 J27 Pin C (WP
(WP 0319, Vol 2).
0451, Vol 3, Figure 10) while
connector is plugged into
variable auger pump.
2. If voltage reads below 0.4 VDC,
turn keyless engine switch to
the OFF position (TM 5-3895-
385-10), and proceed to next
malfunction.
3. Propel controller (Electronic
1. Disconnect main wiring harness
Control Module (ECM)) has
W1 J2 from propel controller
damage or loose pin.
module ECM (WP 0451, Vol 3,
Figure 2).
2. Check propel controller module
1. If propel controller module ECM
ECM for damage or loose pin.
has damage or loose pin,
replace propel controller module
ECM (WP 0399, Vol 2).
2. If no damage is found, proceed
to next malfunction.
4. Main wiring harness has an
1. Measure for continuity (WP
1. If continuity is present, proceed
open circuit.
0443, Vol 3) between main
to next test.
wiring harness W1 J2 Pin 44 and
main wiring harness W1 J27 Pin
D (WP 0451, Vol 3, Figure 10).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
0149-2