TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.
4. Attempt operation with opposite
1. If opposite lights keypad
(left or right) lights keypad (WP
accomplishes operation, notify
field maintenance.
2. If opposite keypad does not
accomplish operation, turn
keyless engine switch to the
proceed to next test.
WARNING
There are m any points o n the BMPM where perso nnel could be injured by moving part s. Turn
BMPM off before performing maintenance. Care should be taken to avoid any pinch points when
performing maintenance. Failure to comply may cause injury or death to personnel.
5. Check for obstructed movement.
1. Remove any obstructions
around hopper wings.
2. If no obstructions are found,
proceed to next test.
6. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
2. Notify field maintenance if
problem persists.
12. Display fails to show engine
1. Check that BATTERY
1. Ensure BATTERY
screen.
DISCONNECT switch is set to
DISCONNECT switch is set to
ON position.
2. If condition is met, proceed to
next test.
2. Check that battery is connected
1. Inspect battery connectors and
properly.
cables for damage or corrosion
2. If problem persists, notify field
maintenance.