TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Screed will not vibrate unless BMPM is moving forward.
3. Ensure BMPM is moving
4. Ensure vibration control knob is
5. If conditions are met, proceed
to next test.
4. Attempt operation with opposite
1. If opposite beacon keypad
(left or right) beacon keypad
accomplishes operation, notify
field maintenance.
2. If opposite keypad does not
accomplish operation, turn
keyless engine switch to the
proceed to next test.
5. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
2. Notify field maintenance if
problem persists.
7. Screed crown fails to operate.
1. Check for Crown Down fault or
1. If no fault is found, proceed to
Crown Up fault indicated on fault
next test.
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
1. Ensure screed crown top bar
2. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.