TM 5-3895-373-34
2.67
REPLACE MAIN SCREED FRAME Continued.
D.
INSTALL Continued.
h.
Install lockwashers (19) and flat washers (18)
onto bolts (17).
WARNING
Sealing compound can cause eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
i.
Apply sealing compound to threads of bolts (17).
j.
Install shield plate (20) and secure with bolts
(17). Tighten bolts to 19 Ib-ft (26 N.m).
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
k.
Apply hydraulic fitting sealant to threads of elbow
(16).
l.
Connect hose (15) to elbow (16).
WARNING
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well-ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
m.
Install lead wire (13) and terminal nut (12) onto
glow plug (14). Apply electrical insulating
varnish to glow plug terminal.
n.
Use tie wraps as necessary to secure wiring and
hoses away from the burner chamber assembly.