TM 5-3895-373-342.67REPLACE MAIN SCREED FRAME Continued.D.INSTALL Continued.h.Install lockwashers (19) and flat washers (18)onto bolts (17).WARNINGSealing compound can cause eyedamage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.i.Apply sealing compound to threads of bolts (17).j.Install shield plate (20) and secure with bolts(17). Tighten bolts to 19 Ib-ft (26 N.m).WARNINGHydraulic fitting sealant can causeeye damage or skin irritation. Washafter skin contact. Wear safetygoggles/glasses when using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with waterand get immediate medical attention.k.Apply hydraulic fitting sealant to threads of elbow(16).l.Connect hose (15) to elbow (16).WARNINGElectrical insulating varnish fumescan be harmful if inhaled. Use only ina well-ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.m.Install lead wire (13) and terminal nut (12) ontoglow plug (14). Apply electrical insulatingvarnish to glow plug terminal.n.Use tie wraps as necessary to secure wiring andhoses away from the burner chamber assembly.GO TO NEXT PAGE2-954