TM 5-3895-373-34
D.
INSTALL - Continued.
7.
INSTALL FITTINGS, TUBES AND HYDRAULIC
HOSES ONTO RIGHT HAND MAIN SCREED
FRAME.
a.
Place machinery wiping towels beneath hydraulic
hoses and fittings.
WARNING
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
b.
From inside of left hand main screed frame, pull
extension screed vibration hoses (54 and 63)
through openings in between main screed
frames until they are completely inside right hand
main screed frame.
c.
Install straight adapters (52 and 53) and (48 and
49) onto main screed frame and secure with hex
nuts (59 through 62).
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
d.
Apply hydraulic fitting sealant to threads of
straight adapters (52 and 53) and (48 and 49)
and to male threads of vibration motor tube (55).
e.
Connect screed extension cylinder tubes (57 and
58) to straight adapters (52 and 53).
f.
Install vibration motor tubes (55 and 56) onto
straight adapters (48 and 49).
g.
Connect left hand extension screed vibration
hose (54) to vibration motor tube (55).
GO TO NEXT PAGE
2-949