TM 5-3895-373-34
D.
INSTALL - Continued.
e.
From inside of right hand main screed frame,
pull extension screed vibration hoses (38 and
39) through openings in between main screed
frames until they are completely inside left hand
main screed frame.
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
f.
Apply hydraulic fitting sealant to threads of
elbows (40 and 41).
g.
Connect left hand extension screed vibration
hoses (38 and 39) to elbows (40 and 41).
h.
Connect left hand extension screed cylinder
hoses (34 and 35) to straight adapters (36 and
37).
GO TO NEXT PAGE
2-951