TM 5-3895-373-34
B.
DISASSEMBLE Continued.
18.
REMOVE SPRING GUIDES, SERVO STOP, AND
SPECIAL SCREW FROM SERVO SPRING.
a.
Remove hex nuts (114 and 120) from special
screw (113).
b.
Pull spring guides (121), special screw (113),
and servo stop (122) from servo spring (123).
19.
REMOVE NEEDLE BEARING.
Do not damage end cap assembly housing
while removing needle bearing. Damage to
sealing surface may occur if care is not taken
when using bearing puller.
a.
Install bearing puller through inside of needle
bearing (124).
b.
Position needle bearing puller on inner surface
of end cap assembly housing.
c.
Pull needle bearing from end cap assembly
housing.
d.
Remove needle bearing from bearing puller.
C.
CLEAN.
Cleaning solvent, P-D-680, is TOXIC and
flammable. Wear protective goggles and
gloves. Use only in a well ventilated area.
Avoid contact with skin, eyes, and clothes, and
do not breathe vapors. Keep away from heat or
flame. Never smoke when using solvent; the
flashpoint for Type m cleaning solvent is 200°F
(93,3°C). Failure to do so may result in injury or
death to personnel.
If personnel become dizzy while using cleaning
solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush
with cold water. If solvent contacts eyes, flush
eyes with water and get immediate medical
attention.
1.
CLEAN ALL PARTS IN CLEANING SOLVENT.
a. Rinse all parts in cleaning solvent.
GO TO NEXT PAGE
2-409