TM 5-3895-373-34
2.29
REPLACE/REPAIR PUMP DRIVE GEARBOX - Continued.
G.
INSTALL Continued.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
o.
Apply hydraulic fitting sealant onto exposed
threads of elbow (12).
p.
Install drain hose (10) onto elbow (12).
q.
Ensure drain plug (9) is tight in drain hose (10).
GO TO NEXT PAGE