TM 5-3895-373-34A.REMOVE Continued.2.DISCONNECT ELECTRICAL CONNECTIONSAND HYDRAULIC HOSES FROM LEFTPROPULSION PUMP.a.Disconnect pump pilot control valve electricalconnector (11) from harness electrical connector(12).Thoroughly clean hydraulic hoses andfittings before disconnecting. Always plugor cap off disconnected fittings to preventintrusion of contaminants. Failure toproperly clean and cap off connectors mayresult in hydraulic system contaminationand equipment damage.b.Wipe off hydraulic hoses and fittings with acleaning cloth.c.Place machinery wiping towels beneathpropulsion pump.Hydraulic oil can be moderately flammableand can be an irritant to the skin, eyes, andrespiratory system. Avoid prolongedexposure. Eye protection and rubbergloves must be worn when working withhydraulic oil.d.Tag and disconnect propulsion pump suctionhose (13) from propulsion pump, usingcombination wrench (Item 116, Appendix D).Plug hose and cap elbow with protective caps.e.Tag and disconnect hydraulic charge filterhoses (14 and 15). Plug hoses and cap elbowand straight adapter with protective caps.f.Tag and disconnect propulsion motor hoses (16and 17) from propulsion pump, usingcombination wrench (Item 115, Appendix D).Plug hoses and cap straight adapters withprotective caps.g.Tag and disconnect case drain hose (18) frompropulsion pump. Plug case drain hose andcap straight adapter with protective caps.h.Cover exposed end of left propulsion pumpwith a plastic bag. Secure bag with rubberbands or tie wraps.GO TO NEXT PAGE2-397