TM 5-3895-373-34A. REMOVE.1.DISCONNECT ELECTRICAL CONNECTIONSAND HYDRAULIC HOSES FROM RIGHTPROPULSION PUMP.a.Disconnect pump pilot control valve electricalconnector (1) from harness electrical connector(2).b.Disconnect hydraulic oil temperature sensorknurled nut (3) and remove harness ring terminal(4).Thoroughly clean hydraulic hoses andfittings before disconnecting. Alwaysplug or cap off disconnected fittings toprevent intrusion of contaminants.Failure to properly clean and cap offconnectors may result in hydraulicsystem contamination and equipmentdamage.c.Wipe off hydraulic hoses and fittings with acleaning cloth.d.Place machinery wiping towels beneathpropulsion pump.GO TO NEXT PAGE2-395