TM 5-3895-373-34
2.22.
REPLACE/REPAIR FUEL TANK - Continued
D.
INSTALL - Continued.
5.
INSTALL FUEL/WATER SEPARATOR.
a.
Install lockwashers (17) and flat washers (18)
onto bolts (16).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
b.
Apply thread locking compound (Item 13,
Appendix B) to threads of bolts (16).
c.
Install fuel/water separator (19) with bolts (16).
Tighten to 19 lb-ft (26 Nm).
6.
INSTALL FUEL LEVEL TRANSMITTER LEAD
WIRES.
a.
Install lead wire (22), lockwasher (21), and hex
nut (20) onto fuel level transmitter (23).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
b.
Apply electrical insulating varnish to fuel level
transmitter terminals.
GO TO NEXT PAGE
2-318