TM 5-3895-373-34
A.
DISASSEMBLE - Continued.
b.
Place bearing body (2) on hydraulic press
frame, with impeller (3) facing up.
c.
Support bearing body (2) with spacer blocks.
d.
Place spacer from universal puller kit on shaft
(4). Select a spacer smaller than shaft
diameter.
e.
Press out assembled shaft (5) through impeller
(3).
2.
PRY SEAL (6) OUT OF IMPELLER END OF
BEARING BODY (2).
B.
CLEAN
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
1.
RINSE BEARING BODY (2) IN CLEANING
SOLVENT. USE A CLEANING BRUSH TO
REMOVE HARD DEPOSITS.
GO TO NEXT PAGE
2-321