TM 5-3895-373-34
D.
INSTALL - Continued.
f.
Install lockwashers (25) and flat washers (26)
onto hex head cap screws (24).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
g.
Apply thread locking compound (Item 14,
Appendix B) to threads of hex head cap
screws (24).
h.
Install three hex head cap screws (24) into tank
mounting feet. Do not tighten at this time.
Do not install into outer right hand mounting
foot at this time.
i.
Install remaining hex head cap screw (24) with
battery ground cable (27) and harness ground
wire (28) in outer right hand mounting foot.
Tighten all cap screws to 37 lb-ft (50 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medial
attention.
j.
Apply electrical insulating varnish to hex head
cap screw (24), battery ground cable (27), and
harness ground wire (28).
GO TO NEXT PAGE
2-317