TM 5-3895-373-34
F.
INSTALL - Continued.
Hydraulic
fitting
sealant
can
cause
eye
damage or skin irritation. Wash after skin
contact. Wear safety goggles/glasses when
using. Avoid contact with eyes or skin. If
sealant contacts eyes, flush eyes with water
and get immediate medical attention.
e.
Apply hydraulic fitting sealant to exposed
threads of straight adapters (50).
f.
Install, but do not tighten, elbows (49) onto
straight adapters (50).
g.
Orient and tighten elbows (49) installed on
left and right auger/conveyor motors (59) as
shown.
4.
CONNECT
HYDRAULIC
HOSES
TO
AUGER/CONVEYOR MOTOR IN AND OUT
PORTS.
a.
Apply hydraulic fitting sealant to threads of
elbows (49) on auger/conveyor motor (59).
Ensure auger/conveyor motor hydraulic hoses
are reconnected to the correct motor in and
out ports. Failure to do so may cause the
auger/conveyor
drive
system
to
jam,
damaging the equipment.
NOTE
The
right
auger/conveyor
motor
turns
counterclockwise and the left auger/conveyor
motor turns clockwise. Porting on the motors
is reversed when going from the right motor
to the left motor.
b.
For the left auger/conveyor motor connect
hydraulic hose (39) to auger/conveyor
motor (59) A port. For the right motor
connect hydraulic hose to motor B port.
c.
For the left auger/conveyor motor connect
hydraulic hose (38) to auger/conveyor
motor (59) B port. For the right motor
connect hydraulic hose to motor A port.
GO TO NEXT PAGE
2-1001